MODEL:QH-VISG2-ED( With b attery ) / QH-VISG2-EN(No battery) Voltage And Current Signal Generator -User manual V202008 Technical Indicators
three power supply modes ,using the mobile phone charger or external 24V can charge/work;
External wiring terminal power supply DC15-30V 1W(without charging)/4W(charging); External MicroUSB-5V current 0.2a (no charge)/0.8A(charge); ( O ptional) The built-in 3.7V lithium battery(1000mah), the maximum charging current is 0.6A , Generally, it takes more than 4 hours to fully charge. It can be used for 1-5 hours; T he voltage output is adjustable ± 10V, E rror <0.05V after calibration, and the driving current < 20mA T he current output is adjustable 0-22ma ,E rror <0.05mA after calibration, and the sampling resistance is <500 Ω; working environment: 0-40 ℃, relative humidity < 80%; S ize (cm) : Shell = 100x60x20 ,The plug p rotruding 9cm,The k nob p rotruding 15cm Wiring diagram 1 GND Power supply negative (input) 2 24V Power supply positive (input) 3 AI+ Current passive mode 24V + input 4 AIO Current signal output 5 AVO Voltage signal output 6 GND Signal ground (connect 1-GND) Voltage signal output :5-AVO 6-GND C ommon active mode of current output : Our output 4- AIO 6- GND corresponds to PLC I + I -! Current passive mode : The PIN 3-AI+ is externally connected to 24V+, and then output from 4-AIO to control the external 24V current.Our meter is equivalent to an adjustable resistance;Therefore, it is called passive mode. U sage :
Operation panel and operation instructions Switching - Adjust the display V or I, press the "MODE" key to switch and adjust the display V or I MODE The indicator light shows what state it is in and what mode the system operation is in; The original output will continue to output After switching, but not in the adjustment status; Turn on the battery switch to check the battery status and quantity B at tery status indicator: B at tery indicator Green Yellow Red T winkle Green not T winkle (External power) capacity ≥8 0% ≥40% >0 C harging 。。。 F ull Hold the "MODE" key for 1 second and the digital tube flashes for 5 seconds to display the battery voltage; Digital adjustment and parameter setting : ( Forewarned : Push Down The Knob Is “OK
”,Clockwise Rotation The Knob One Pulse Is” + ”, Anticlockwise Rotation The Knob One Pulse Is” - ” ) Short Press “OK” To Save The Output Value,Digital Tube Display "..." After loosening, Saved Successfully, The Output Value Is This Saved Value After The Next Boot; When We Debug The Device, We Need To Adjust The Output Value Randomly, As Long As The Knob Is Not Pressed, It Will Still Be The Saved Value After Rebooting; Hold The “OK” For 2 Seconds To Enter The Setting State.,Display”F001”(Parameter Number 001) ; Turn the knob to change the parameter number, You need to enter a password when enter F002 or F100 :
F001->F002 enter a password “ + - - + ( Turn the knob )”, Then press the knob to enter; F001->F100 enter a password “ + - + - ( Turn the knob )” ,Then press the knob to enter; Press "Ok" to enter the setting of corresponding parameter value, and turn the knob to modify parameters ; Press "Ok" to save the parameter, exit the parameter setting, and display the next parameter number (after setting the F001 value without entering the password, the normal operation screen will enter) ; Rotate the knob directly to the last parameter number, press the "OK" key, and the setting is completed; If no operation on the parameter setting screen exceeds 10s, it will exit the setting state ; Voltage setting parameters. please read section 3.4 before operating, especially to enter a password : N umber Description N ote D efault F001 A djust Mode 0 :Coarse 1 : F ine 2 : Point Mode (Need to set F100>0) 0 F002 Output M ode 0:±10V 1:±5V 2:0-10V 3:2-10V 4:0-5V 5:1-5V 6:0-3.3V 7:0-2.5V 8:0-1V 9:-10V-0V 2 F003 Display M ode 0:Real Voltage 1:P ercentage 0-100.0% 2:50HZ 3:1500 0 F004 Add Or Sub Num For Knob ’ s P ulse ( Coarse ) 1-50 No D ecimal P oint C oncept (1-50)×10 1 F005 Add Or Sub Num For Knob ’ s P ulse ( F ine ) 1-50 No D ecimal P oint C oncept (1-50)×1 1 F006 -10V Calibration V alue -199 -- +199 I nternal R eference , Please B e C areful F007 0V Calibration Value -199 -- +199 I nternal R eference , Please B e C areful F008 +10V Calibration V alue -199 -- +199 I nternal R eference , Please B e C areful F 100 Point Mode Num 0: Point Mode Not Use 2-9: Point Num 0 F 101 … F109 Point Output Value range : -10V to 10V You can set as many values as there are points Current setting parameters. please read section 3.4 before operating, especially to enter a password : N umber Description N ote D efault F001 A djust Mode 0 :Coarse 1 : F ine 2 : Point Mode (Need to set F100>0) 0 F002 Output M ode 0:0-20mA 1:4-20mA 2:0-22mA 0 F003 Display M ode 0:Real Voltage 1:P ercentage 0-100.0% 2:50HZ 0 F004 Add Or Sub Num For Knob ’ s P ulse ( Coarse ) 1-50 No D ecimal P oint C oncept (1-50)×10 1 F005 Add Or Sub Num For Knob ’ s P ulse ( F ine ) 1-50 No D ecimal P oint C oncept (1-50)×1 1 F008 Calibration Value -999 -- +999 I nternal R eference , Please B e C areful F 100 Point Mode Num 0: Point Mode Not Use 2-9: Point Num 0 F 101 … F109 Point Output Value range : 0-22mA You can set as many values as there are points current problem detection: the possibility of the current not output is very small,you can measured the voltage of 4-AIO 6-GND with a multimeter, if it is >20V, than current file of your multimeter is broken or gear is wrong, because there are voltage must be current, try change a multimeter, multimeter current file inside a fuse is easy to burn; Please R ead T his M anual C arefully B efore W iring , Turn O ff T he P ower A nd T hen C onnect ; Payment Shipping Refund Payment
Customer satisfaction is our top goal. We believe our items are so outstanding. All products are quality checked. They are new and in good condition when shipped to our customers. We are convinced you will be happy with your Purchase.
If product is defective or damage upon arrival, or wrong product shipped, please contact us immediately. Returns accepted within 30 days of delivery date and item must be in original new condition.
Please contact us first if you have any problems/questions/concerns. We will be happy to resolve any issues you may have in a cordial and friendly manner.
Shipping
Please fill in the correct address and zip code and I will ship quickly! Refund If the item is defect when you receive it or you are not satisfied with it, please return it within 30 days for a replacement or money back. But the items must be back in factory condition. Please contact us and double check the return address before you return it.
Returns Accepted for this item if it's within 30 Days