Description:Sensing InpuuutVoltage 220 / 380 / 440 VAC, 1 phase2 wireDIP switch selectableFrequency 50 / 60 Hz, DIP switch selectablePower InputVoltage 100 ~ 300 VAC, 1 phase 2 wireOutputVoltage Max. 90 VDC @ 240 VAC inputCurrent Continuous 5AIntermittent 7A for 10 secResistance Min. 15 ohm Max. 100 ohmVoltage Regulation< ± 0.5% ( with 4% engine governing )Voltage Build-upResidual voltage at AVR terminal > 5 VACThermal Drift0.03% per °C change in AVR ambientExternal Volts Adjustmen± 7% with 1K ohm 1 watt trimmerEMI SuppressionInternal electromagnetic interference filteringUnit Power DissipationMax. 8 wattUnder Frequency Protection (Factory Setting)60 Hz system presets knee point at 55 Hz50 Hz system presets knee point at 45 HzSoft Sta...
AVR EA05A Automatic Voltage Regulator Controller For Generator Genset Parts Description: Sensing Inpuuut Voltage 220 / 380 / 440 VAC, 1 phase2 wire DIP switch selectable Frequency 50 / 60 Hz, DIP switch selectable Power Input Voltage 100 ~ 300 VAC, 1 phase 2 wire Output Voltage Max. 90 VDC @ 240 VAC input Current Continuous 5A Intermittent 7A for 10 sec Resistance Min. 15 ohm Max. 100 ohm Voltage Regulation < ± 0.5% ( with 4% engine governing ) Voltage Build-up Residual voltage at AVR terminal > 5 VAC Thermal Drift 0.03% per °C change in AVR ambient External Volts Adjustmen ± 7% with 1K ohm 1 watt trimmer EMI Suppression Internal electromagnetic interference filtering Unit Power Dissipation Max. 8 watt Under Frequency Protection (Factory Setting) 60 Hz system presets knee point at 55 Hz 50 Hz system presets knee point at 45 Hz Soft Start Ramp Time 3 sec. Dimensions 101mm L * 69mm W * 47.5mm H Weight 183g ± 2% 2. WIRING When generator supply is over load, N phase will be different with the sharing load by 3 phases (load imbalance). Hence, the voltage from N phase to 3 phases (R.S.T.) will be altered. When the rated voltage of the traditional single input’s AVR is above 220V, it will increase the voltage drift rate by using N phase as the detective input. It will also cause the voltage imbalance. EA05A can improve the above situation, and increase the generator’s rated voltage usage space,such as 380V, 440V. We can all detect by the “phase voltage”. 1. When the rated phase voltage of the generator is 220VAC, the input terminals B, C and sensing terminals A, C can join together (as show as figure3. It’s the original setting).or connect independent.(as show as figure2). 2. When the rated phase voltage of the generator is 380V, 440V, the input terminals B, C and sensing terminals A, C must separate connect the wiring (as show as Figure 4 or figure 5). The voltage between B and C must not be over 300 VAC. 3. F+ F- terminals connect to the generator field. (J and K) FEXT.VR is the potentiometer (1KΩ 1W). These two terminals must be by-pass when external potentiometer is needless. P.S. : A, B, C, F+ F- the usage of wire gauge are AWG16 or 1.25 mm2 85。 C above 600V. The EXT.VR connection wires must be made of isolated wiring. 3. ADJUSTMENTS The voltage setting for 220V/380V/440V and the frequency setting for 50/60HZ is show in figure7. Please check the voltage/frequency selector setting is correct before start the generator. CAUTION : THE GENERATOR OR AVR MAY BE DAMAGED IF THE VOLTAGE / FREQUENCY SELECTOR SETTING IS INCORRECT. UFRO DIP: 1. Before you turn on the generator, please turn the voltage adjustment and stability adjustment full anti-clockwise. After the generator is on and run stably, turn the voltage adjustment clockwise to reach the required out voltage. (If there is an external potentiometer, turn the external potentiometer to the middle position before adjust internal voltage potentiometer.) 2. Adjust “Stability Adjustment” clockwise slowly to change the feedback time between AVR and the generator. If the adjustment is too big, it might cause the voltage instable. If too small, the load voltage will change too much at heavy load. Our suggestion is to trace by the multi-meter DCV. To adjust “stability adjustment”, you just need to make the multi-meter waving smaller. It can also improve the full load’s voltage drift rate. 4. FIELD FLASHING When the regulator is operated with the generator for the first time, the polarity of residual magnetism may be reversed or too small to achieve the necessary build-up voltage for the regulator. If reversing the field connections does not induce build-up, and the residual voltage is less than the specified value of 5 Vac, shut down the Prime-mover and proceed with the following steps : 1. With the Prime-mover at rest and the regulator’s field output wires disconnected, apply a DC source ( NOT grounded ) of not more than 3~12 Vdc with Positive to F+ and Negative to F-, in series with a current-limiting resistor of 3~5 ohms 20 watt. (The set battery is a suitable source.) 2. Allow approximately 3 seconds before removing the DC source. 3. With the voltage regulator disconnected ( wires 3 and 4 ), start the prime mover and measure the “ residual ” voltage available at the auxiliary winding. If this voltage is greater than 5 Vac, reconnect voltage regulator, and voltage build-up should be successful. If less than 5 Vac is measured, repeat field flashing procedure. 4. If repeating steps a. and b. does not result in generator voltage build-up, and residual is greater than 5 Vac, replace voltage regulator. Package Include: 1 x Automatic Voltage Regulator Controller AVR EA05A Genset Parts 1 x product Instructions Item Specifics Brand ign-club MPN ICC470061 Equipment Type AVR Model EA05A Warranty 1 year
Payment You can use Paypal or a credit card with VISA or MasterCard logo or apple pay or Googel pay
Shipping The item will be shipped within 3 day on payment received except the holidays.(except weekends & official holidays). You can log on to Pricetronic to check your logistics tracking number. Please confirm address before purchase, and cannot change address once purchased. If you need to receive the item quickly, please contact us, you can pay the postage to choose other logistics.
Returns Please contact us first when return, exchange and refund is required. Any direct return of purchased items will not be processed. Item must be returned in new condition, as received with all accompanied accessories and literature, including the factory carton. Shipping, handling is not refundable unless item is returned because of defect. If the product is defective or damage upon arrival,please contact us immediately,we will provide the solve the problem. Returns accepted within 30 days of delivery date and item must be in original new condition.
Contact Us Our goal is complete customer satisfaction. We will be very honored to provide you with quality service. If there is an issue with shipping or the item you purchased please contact us via Pricetronic message or call us before opening a case or leaving feedback.We will try our best to resolve any kind of issue.
Shop Category
Hot Item USD 26.15 USD 20.14 USD 38.09 USD 15.10 USD 16.32
Picture
New List Item USD 18.10 USD 18.37 USD 16.91 USD 34.85 USD 31.21
Help & Info
Payment Policy
Shipping Policy
Return Policy
FAQ
About Us
AVR EA05A Automatic Voltage Regulator Controller For Generator Genset Parts Description: Sensing Inpuuut Voltage 220 / 380 / 440 VAC, 1 phase2 wire DIP switch selectable Frequency 50 / 60 Hz, DIP switch selectable Power Input Voltage 100 ~ 300 VAC, 1 phase 2 wire Output Voltage Max. 90 VDC @ 240 VAC input Current Continuous 5A Intermittent 7A for 10 sec Resistance Min. 15 ohm Max. 100 ohm Voltage Regulation < ± 0.5% ( with 4% engine governing ) Voltage Build-up Residual voltage at AVR terminal > 5 VAC Thermal Drift 0.03% per °C change in AVR ambient External Volts Adjustmen ± 7% with 1K ohm 1 watt trimmer EMI Suppression Internal electromagnetic interference filtering Unit Power Dissipation Max. 8 watt Under Frequency Protection (Factory Setting) 60 Hz system presets knee point at 55 Hz 50 Hz system presets knee point at 45 Hz Soft Start Ramp Time 3 sec. Dimensions 101mm L * 69mm W * 47.5mm H Weight 183g ± 2% 2. WIRING When generator supply is over load, N phase will be different with the sharing load by 3 phases (load imbalance). Hence, the voltage from N phase to 3 phases (R.S.T.) will be altered. When the rated voltage of the traditional single input’s AVR is above 220V, it will increase the voltage drift rate by using N phase as the detective input. It will also cause the voltage imbalance. EA05A can improve the above situation, and increase the generator’s rated voltage usage space,such as 380V, 440V. We can all detect by the “phase voltage”. 1. When the rated phase voltage of the generator is 220VAC, the input terminals B, C and sensing terminals A, C can join together (as show as figure3. It’s the original setting).or connect independent.(as show as figure2). 2. When the rated phase voltage of the generator is 380V, 440V, the input terminals B, C and sensing terminals A, C must separate connect the wiring (as show as Figure 4 or figure 5). The voltage between B and C must not be over 300 VAC. 3. F+ F- terminals connect to the generator field. (J and K) FEXT.VR is the potentiometer (1KΩ 1W). These two terminals must be by-pass when external potentiometer is needless. P.S. : A, B, C, F+ F- the usage of wire gauge are AWG16 or 1.25 mm2 85。 C above 600V. The EXT.VR connection wires must be made of isolated wiring. 3. ADJUSTMENTS The voltage setting for 220V/380V/440V and the frequency setting for 50/60HZ is show in figure7. Please check the voltage/frequency selector setting is correct before start the generator. CAUTION : THE GENERATOR OR AVR MAY BE DAMAGED IF THE VOLTAGE / FREQUENCY SELECTOR SETTING IS INCORRECT. UFRO DIP: 1. Before you turn on the generator, please turn the voltage adjustment and stability adjustment full anti-clockwise. After the generator is on and run stably, turn the voltage adjustment clockwise to reach the required out voltage. (If there is an external potentiometer, turn the external potentiometer to the middle position before adjust internal voltage potentiometer.) 2. Adjust “Stability Adjustment” clockwise slowly to change the feedback time between AVR and the generator. If the adjustment is too big, it might cause the voltage instable. If too small, the load voltage will change too much at heavy load. Our suggestion is to trace by the multi-meter DCV. To adjust “stability adjustment”, you just need to make the multi-meter waving smaller. It can also improve the full load’s voltage drift rate. 4. FIELD FLASHING When the regulator is operated with the generator for the first time, the polarity of residual magnetism may be reversed or too small to achieve the necessary build-up voltage for the regulator. If reversing the field connections does not induce build-up, and the residual voltage is less than the specified value of 5 Vac, shut down the Prime-mover and proceed with the following steps : 1. With the Prime-mover at rest and the regulator’s field output wires disconnected, apply a DC source ( NOT grounded ) of not more than 3~12 Vdc with Positive to F+ and Negative to F-, in series with a current-limiting resistor of 3~5 ohms 20 watt. (The set battery is a suitable source.) 2. Allow approximately 3 seconds before removing the DC source. 3. With the voltage regulator disconnected ( wires 3 and 4 ), start the prime mover and measure the “ residual ” voltage available at the auxiliary winding. If this voltage is greater than 5 Vac, reconnect voltage regulator, and voltage build-up should be successful. If less than 5 Vac is measured, repeat field flashing procedure. 4. If repeating steps a. and b. does not result in generator voltage build-up, and residual is greater than 5 Vac, replace voltage regulator. Package Include: 1 x Automatic Voltage Regulator Controller AVR EA05A Genset Parts 1 x product Instructions Payment Shipping Returns Contact Us About Us You can use Paypal or a credit card with VISA or MasterCard logo or apple pay or Googel pay The item will be shipped within 3 day on payment received except the holidays.(except weekends & official holidays). You can log on to Pricetronic to check your logistics tracking number. Please confirm address before purchase, and cannot change address once purchased. If you need to receive the item quickly, please contact us, you can pay the postage to choose other logistics. Please contact us first when return, exchange and refund is required. Any direct return of purchased items will not be processed. Item must be returned in new condition, as received with all accompanied accessories and literature, including the factory carton. Shipping, handling is not refundable unless item is returned because of defect. If the product is defective or damage upon arrival,please contact us immediately,we will provide the solve the problem. Returns accepted within 30 days of delivery date and item must be in original new condition. Our goal is complete customer satisfaction. We will be very honored to provide you with quality service. If there is an issue with shipping or the item you purchased please contact us via Pricetronic message or call us before opening a case or leaving feedback.We will try our best to resolve any kind of issue. All rights reserved.
Returns Accepted for this item if it's within 30 Days